Tech News, Magazine & Review WordPress Theme 2017
  • Home
  • Supply Chain Updates
  • Global News
  • Contact Us
  • Home
  • Supply Chain Updates
  • Global News
  • Contact Us
No Result
View All Result
No Result
View All Result
Home Supply Chain Updates

Microshunt moves aqueous to ocular surface

usscmc by usscmc
January 8, 2020
‘Arc of material’ presented at private equity meeting
Share on FacebookShare on Twitter

A new glaucoma microshunt that drains the aqueous onto the ocular surface is advancing its way through studies.

Patrick J. Riedel, MD
Patrick J. Riedel

“It is the first and only device shunting the aqueous to a location that is not the subconjunctival space, nor the conventional outflow system or the suprachoroidal space. It is a novel mechanism of action, very simple and direct, with no possible source of downstream resistance, such as episcleral venous pressure,” Patrick J. Riedel, MD, said in an interview with Ocular Surgery News.

The Beacon Aqueous Microshunt (BAM, MicroOptx), formerly the Brown Glaucoma Implant, derived from the name of its inventor, has an overall length of 3.1 mm, with an internal flow channel of 30 µm × 48 µm and an external flange of 1.7 mm. It is inserted under topical anesthesia through a small incision in the peripheral cornea, with the external flange resting on the ocular surface.

“The procedure takes less than 1 minute to perform. Flow through the channel can be seen immediately, the aqueous humor is shunted directly to the tear film, and no peripheral flow is observed,” Riedel said.

Through a combination of advanced biomaterials, microengineering and nanotechnologies, the BAM aims to overcome the problems and limitations of competing technologies in terms of both effectiveness and safety.

One major advantage is the ability to prevent retrograde migration of pathogens into the eye, which relies on the combination of two factors. One is the shear stress from the laminar flow of the aqueous.

“Aqueous flows through the channel at such a velocity that pathogens cannot adhere to the walls of the device,” Riedel said.

But even more important is the material the channel is made of, which prevents adherence.

“Polyethylene glycol is a superhydrophilic material to which bacteria cannot cling,” Riedel said.

Preclinical studies over many months have shown that no intraocular infection occurs and no pathogens are present in the aqueous even when infection is induced on the ocular surface.

In addition, the aqueous outflow constantly bathes the cornea with lubricating, nutrient-rich aqueous humor, which may be effective for treating dry eye and ocular surface disease.

“The Schirmer test shows significant increase at 6 months as compared with baseline, which has huge potential for improving tear film composition and volume. This additional benefit of the device will be evaluated in studies in addition to IOP,” Riedel said.

IOP lowering with no medications

Twenty-six patients have been implanted with this device within the first clinical studies carried out in the United States and Europe, and at least half of them have reached 1 year of follow-up.

Mean IOP at 6 months was 13 mm Hg without medications as compared with 27 mm Hg at baseline with medications. A greater than 20% reduction of IOP at the last visit was achieved by 87% of patients, with complete elimination of the need for medications in nearly all patients. The majority of patients found the device extremely comfortable and said they were satisfied or extremely satisfied.

No sight-threatening complications, no infections, no uveitis, no dislocations and no device migration occurred. In six eyes, device blockage occurred in the early postoperative period for reasons that have not yet been clarified. All cases but one resolved completely with minimal or no manipulation or with intervention such as YAG laser. One patient in the European cohort had the device explanted due to persistent blockage. Two patients reported mild irritation.

“Our hope is that we will continue to see these good outcomes and excellent safety profile with no infection in the long term. Meanwhile, the design is undergoing further improvements. The new prototype has a round rather than a rectangular or square flow channel to improve flow dynamics and prevent blockage,” Riedel said.

A further prospective multicenter study will evaluate safety and effectiveness of the device in refractory glaucoma in 70 eyes of 70 patients from 12 study sites.

Improving accessibility to glaucoma care

If long-term data confirm the good results achieved so far, the BAM could become the least invasive option in the MIGS panorama.

“It could be used in all forms of glaucoma and across the glaucoma spectrum from mild to severe. Also, unlike other devices, it is conceived as a stand-alone procedure rather than an adjunct to cataract surgery,” Riedel said.

The ease of implantation and the intrinsic infection barrier properties of the device make it suitable for implantation in a minor operating room as opposed to a surgical suite.

“For this and other reasons, it could be an ideal solution for glaucoma in developing regions. It is quick and easy to implant, and you can treat a lot of patients with a simple procedure. It could greatly improve accessibility to glaucoma care worldwide,” Riedel said. – by Michela Cimberle

  • For more information:
  • Patrick J. Riedel, MD, can be reached at Minnesota Eye Consultants, 11091 Ulysses St. NE, Blaine, MN 55434; email: [email protected].

Disclosure: Riedel reports he is a consultant for MicroOptx.

A new glaucoma microshunt that drains the aqueous onto the ocular surface is advancing its way through studies.

Patrick J. Riedel, MD
Patrick J. Riedel

“It is the first and only device shunting the aqueous to a location that is not the subconjunctival space, nor the conventional outflow system or the suprachoroidal space. It is a novel mechanism of action, very simple and direct, with no possible source of downstream resistance, such as episcleral venous pressure,” Patrick J. Riedel, MD, said in an interview with Ocular Surgery News.

The Beacon Aqueous Microshunt (BAM, MicroOptx), formerly the Brown Glaucoma Implant, derived from the name of its inventor, has an overall length of 3.1 mm, with an internal flow channel of 30 µm × 48 µm and an external flange of 1.7 mm. It is inserted under topical anesthesia through a small incision in the peripheral cornea, with the external flange resting on the ocular surface.

“The procedure takes less than 1 minute to perform. Flow through the channel can be seen immediately, the aqueous humor is shunted directly to the tear film, and no peripheral flow is observed,” Riedel said.

Through a combination of advanced biomaterials, microengineering and nanotechnologies, the BAM aims to overcome the problems and limitations of competing technologies in terms of both effectiveness and safety.

One major advantage is the ability to prevent retrograde migration of pathogens into the eye, which relies on the combination of two factors. One is the shear stress from the laminar flow of the aqueous.

“Aqueous flows through the channel at such a velocity that pathogens cannot adhere to the walls of the device,” Riedel said.

But even more important is the material the channel is made of, which prevents adherence.

“Polyethylene glycol is a superhydrophilic material to which bacteria cannot cling,” Riedel said.

Preclinical studies over many months have shown that no intraocular infection occurs and no pathogens are present in the aqueous even when infection is induced on the ocular surface.

In addition, the aqueous outflow constantly bathes the cornea with lubricating, nutrient-rich aqueous humor, which may be effective for treating dry eye and ocular surface disease.

“The Schirmer test shows significant increase at 6 months as compared with baseline, which has huge potential for improving tear film composition and volume. This additional benefit of the device will be evaluated in studies in addition to IOP,” Riedel said.

IOP lowering with no medications

Twenty-six patients have been implanted with this device within the first clinical studies carried out in the United States and Europe, and at least half of them have reached 1 year of follow-up.

PAGE BREAK

Mean IOP at 6 months was 13 mm Hg without medications as compared with 27 mm Hg at baseline with medications. A greater than 20% reduction of IOP at the last visit was achieved by 87% of patients, with complete elimination of the need for medications in nearly all patients. The majority of patients found the device extremely comfortable and said they were satisfied or extremely satisfied.

No sight-threatening complications, no infections, no uveitis, no dislocations and no device migration occurred. In six eyes, device blockage occurred in the early postoperative period for reasons that have not yet been clarified. All cases but one resolved completely with minimal or no manipulation or with intervention such as YAG laser. One patient in the European cohort had the device explanted due to persistent blockage. Two patients reported mild irritation.

“Our hope is that we will continue to see these good outcomes and excellent safety profile with no infection in the long term. Meanwhile, the design is undergoing further improvements. The new prototype has a round rather than a rectangular or square flow channel to improve flow dynamics and prevent blockage,” Riedel said.

A further prospective multicenter study will evaluate safety and effectiveness of the device in refractory glaucoma in 70 eyes of 70 patients from 12 study sites.

Improving accessibility to glaucoma care

If long-term data confirm the good results achieved so far, the BAM could become the least invasive option in the MIGS panorama.

“It could be used in all forms of glaucoma and across the glaucoma spectrum from mild to severe. Also, unlike other devices, it is conceived as a stand-alone procedure rather than an adjunct to cataract surgery,” Riedel said.

The ease of implantation and the intrinsic infection barrier properties of the device make it suitable for implantation in a minor operating room as opposed to a surgical suite.

“For this and other reasons, it could be an ideal solution for glaucoma in developing regions. It is quick and easy to implant, and you can treat a lot of patients with a simple procedure. It could greatly improve accessibility to glaucoma care worldwide,” Riedel said. – by Michela Cimberle

  • For more information:
  • Patrick J. Riedel, MD, can be reached at Minnesota Eye Consultants, 11091 Ulysses St. NE, Blaine, MN 55434; email: [email protected].

Disclosure: Riedel reports he is a consultant for MicroOptx.

usscmc

usscmc

No Result
View All Result

Recent Posts

  • How Hapag Lloyd captured a major market share in the Container Shipping Industry in USA
  • Why USA’s East Coast is the Favorite Destination for Manufacturing Companies
  • How Trade Relations Between the USA and UK Improved After Keir Starmer Became Prime Minister
  • Tips and Tricks for Procurement Managers to Handle Their Supplier Woes
  • The Crazy Supply Chain of Walmart Spanning Across the Globe

Recent Comments

  • Top 5 Supply Chain Certifications that are in high demand | Top 5 Certifications on Top 5 Globally Recognized Supply Chain Certifications
  • 3 Best Procurement Certifications that are most valuable | Procurement Newz on Top 5 Globally Recognized Supply Chain Certifications

Archives

  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
  • May 2023
  • April 2023
  • March 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • September 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022
  • March 2022
  • February 2022
  • January 2022
  • December 2021
  • November 2021
  • October 2021
  • September 2021
  • August 2021
  • July 2021
  • June 2021
  • May 2021
  • April 2021
  • March 2021
  • February 2021
  • January 2021
  • December 2020
  • November 2020
  • October 2020
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • March 2020
  • February 2020
  • January 2020
  • December 2019
  • November 2019
  • September 2019

Categories

  • Global News
  • Supply Chain Updates

Meta

  • Log in
  • Entries feed
  • Comments feed
  • WordPress.org
  • Antispam
  • Contact Us
  • Disclaimer
  • Home
  • Privacy Policy
  • Terms of Use

© 2025 www.usscmc.com

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
SAVE & ACCEPT
No Result
View All Result
  • Home
  • Supply Chain Updates
  • Global News
  • Contact Us

© 2025 www.usscmc.com