On Dec. 3, 1999, at 6:13 p.m., a fire was reported by an off-duty police officer in the vacant Worcester Cold Storage Warehouse at 266 Franklin St. At 6:15 p.m., fire alarm toned out box 1438 for a reported fire at 236 Franklin St. (The address would be corrected.)  Worcester Pic6

The initial response was Worcester Fire Department (WFD) Engines 1, 6, 12 and 13, Ladders 1 and 5, Rescue 1 and Car 3. Upon arrival at 6:16 p.m., Engine 1’s officer reported heavy smoke coming from the roof. Companies entered and started searching for the fire. At 6:19 p.m., Car 3 arrived and ordered a second alarm, bringing two more engines and one more ladder. Crews in the building discovered heavy fire in the elevator shaft and called for lines to be deployed. A report came in: Two homeless individuals were inside. Rescue 1 split into two-person teams and started a search of the building. Conditions deteriorated; visibility went to zero. One of the two-person teams became disoriented on an upper floor; other crews started searching for them. The missing team called command: They were running low on air and needed immediate assistance.

As crews searched, conditions worsened. Two more two-person crews lost their bearings. While the search continued, one officer reported that the building’s integrity was starting to fail. Several attempts were made to radio the missing firefighters; there was no answer. At 8:00 p.m., all companies in the building were ordered out by the incident commander (IC) for a defensive attack.

For the next eight days, crews worked around the clock to locate the bodies of the six firefighters who were lost. They are:

  • Paul Brotherton
  • Tim Jackson
  • Jeremiah (Jerry) Lucey
  • Lt. James (Jay) Lyons
  • Joseph McGuirk
  • Lt. Thomas (Tom) Spencer

Worcester Paul BrothertonPaul Brotherton

Worcester Tim JacksonTim JacksonWorcester Jay LyonsJay LyonsWorcester Joseph McguirkJoseph McGuirkWorcester Tom SpencerTom SpencerWorcester Tim JacksonTim JacksonIt was determined that the homeless people left the building as much as an hour before the fire was reported. The fire was believed to be caused by a fallen

candle.

NIOSH recommendations

After the National Institute for Occupational Safety and Health’s (NIOSH) lengthy investigation, the agency’s firefighter fatality review made 13 recommendations. Here is how WFD has responded to those:

Recommendation #1: Fire departments should ensure that inspections of vacant buildings and pre-fire planning are conducted and that they cover all potential hazards, structural building materials and renovations that might be encountered during a fire. The IC would have necessary structural information to make informed decisions and to implement an appropriate plan of attack.

Response: WFD inspects vacant buildings and notes dangers to firefighting operations.

Recommendation #2: Fire departments should ensure that the incident command system (ICS) is fully implemented at the fire scene.

Response: WFD trains all personnel in the ICS and uses the ICS for every incident.

Recommendation #3: Fire departments should ensure that a separate, independent Incident Safety Officer is appointed when activities, size of fire or need occurs, such as multiple-alarm fires, or responds automatically to pre-designated fires.

Response: WFD created a full-time safety officer position to respond to larger-scale incidents. A new Safety Division has a district chief as a division head; a captain is assigned to each working group.

Recommendation #4: Fire departments should ensure that standard operating procedures (SOPs) and equipment are adequate and sufficient to support the volume of radio traffic at multiple-alarm fires.

Response: A portable radio is available for every position on the apparatus.

Recommendation #5: Fire departments should ensure that the IC maintains close accountability for all fire-scene personnel.

Response: Personnel have accountability tags; apparatus have accountability boards.

Recommendation #6: Fire departments should use guide ropes/tag lines that are securely attached to permanent objects at entry portals and should place high-intensity floodlights at entry portals to assist lost or disoriented firefighters for emergency escape.

Response: Each SCBA has a search rope bag that’s attached to it.

Recommendation #7: Fire departments should establish a rapid intervention team (RIT) for positioning upon arrival.

Response: A RIT is at every reported fire.

Recommendation #8: An overall health and safety program should be implemented.

Response: The Safety Division is responsible for WFD’s Health and Safety Program.

Recommendation #9: Fire departments should consider using a marking system when conducting searches.

Response: WFD is evaluating plans to deal with the marking of rooms during searches.

Recommendation #10: Fire departments should identify dangerous vacant buildings by affixing warning placards to doorways, etc., through which firefighters might enter.

Response: WFD inspects vacant structures; a placard regarding dangers the structures pose to firefighter operations is posted.

Recommendation #11: Fire departments should ensure officers enforce the mandatory (SCBA) mask rule per administrative guidelines established by the department.

Response: WFD has always maintained a mandatory mask rule per guidelines.

Recommendation #12: Fire departments should explore the use of thermal-imaging cameras to locate lost or downed firefighters and civilians in fire environments.

Response: WFD purchased thermal-imaging cameras for each apparatus.
Worcester TableA look at how the Worcester, MA, Fire Department has changed.

Recommendation #13: Manufacturers and research organizations should conduct research into refining existing and developing new technology to track the movement of firefighters who are on the fireground.

Response: WFD now has personnel-tracking capabilities on all SCBA.

Changes to WFD

New training is focused on key areas, including RIT and firefighter self-awareness and self-rescue. WFD secured buildings to conduct scenarios and smoke machines to recreate real-life incidents and to perform actual rescues of down or lost firefighters.

The Training Division now runs a back-to-basics program by which companies review basic skills and new techniques.

A mandatory monthly in-service training is set for all companies. Officer training focuses on tactics and strategies. The department continues work on RIT capabilities as better techniques are developed.

Initial work to establish the specific responsibilities of Safety Division captains continues.

The division also is tasked with taking steps toward the prevention of cancer. It mandated the issuing of two sets of gear to all personnel and the installation of extractors in stations, so personnel can clean their gear after an incident. Air is monitored during overhaul. Fire scenes are evaluated on an ongoing basis to identify problems that might arise as time passes.

The division is developing a program that will permit crews to perform gross decontamination at the scene, with particular focus on the head and neck.

The division inspects all PPE and investigates all fireground injuries and all apparatus accidents. The inclusion of SCBA repairmen on staff facilitates routine maintenance and annual testing of PPE.

With wellness in mind, the department conducts an annual air-consumption drill that involves each member. It also provides access to training programs that are run by an outside specialist, with a focus on exercise and lifestyle changes, including better sleep and eating habits. 

usscmc

usscmc

No Result
View All Result

Recent Posts

  • How Hapag Lloyd captured a major market share in the Container Shipping Industry in USA
  • Why USA’s East Coast is the Favorite Destination for Manufacturing Companies
  • How Trade Relations Between the USA and UK Improved After Keir Starmer Became Prime Minister
  • Tips and Tricks for Procurement Managers to Handle Their Supplier Woes
  • The Crazy Supply Chain of Walmart Spanning Across the Globe

Recent Comments

  • Top 5 Supply Chain Certifications that are in high demand | Top 5 Certifications on Top 5 Globally Recognized Supply Chain Certifications
  • 3 Best Procurement Certifications that are most valuable | Procurement Newz on Top 5 Globally Recognized Supply Chain Certifications

Archives

  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
  • May 2023
  • April 2023
  • March 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • September 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022
  • March 2022
  • February 2022
  • January 2022
  • December 2021
  • November 2021
  • October 2021
  • September 2021
  • August 2021
  • July 2021
  • June 2021
  • May 2021
  • April 2021
  • March 2021
  • February 2021
  • January 2021
  • December 2020
  • November 2020
  • October 2020
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • March 2020
  • February 2020
  • January 2020
  • December 2019
  • November 2019
  • September 2019

Categories

  • Global News
  • Supply Chain Updates

Meta

  • Log in
  • Entries feed
  • Comments feed
  • WordPress.org
  • Antispam
  • Contact Us
  • Disclaimer
  • Home
  • Privacy Policy
  • Terms of Use

© 2025 www.usscmc.com

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
SAVE & ACCEPT
No Result
View All Result
  • Home
  • Supply Chain Updates
  • Global News
  • Contact Us

© 2025 www.usscmc.com